VS2000V Veterinary Vital Signs Monitor

This VS2000V veterinary vital signs monitor is intended to be used in special procedure labs and other areas of a veterinary hospital or clinic where veterinary monitoring systems are needed. The monitor package includes 3-lead or 5-lead electrocardiography (ECG), noninvasive blood pressure (NIBP), temperature (TEMP) and pulse oximetry (SpO2).The device permits patient monitoring with adjustable alarm limits as well as visible and audible alarm signals. The monitor provides fast, reliable measurements for patientsranging from cats to horses when using the appropriate accessories.

VS2000V Veterinary Vital Signs Monitor

Features of VS2000V Monitor:

  1. 7″ high resolution color LCD display with adjustable brightness.
  2. Lightweight and portable, easy for veterinarians to carry out.
  3. Built-in rechargeable lithium battery for long term continuous operation.
  4. 3 leads and 5 leads ECG cable are selectable.
  5. Variety of NIBP Cuffs for different size animals.
  6. Expanded heart rate values and Veterinary specific SpO2 sensors to accommodate a variety of species.
  7. Widely used in pet hospitals and animal clinics etc.
  8. Two-year warranty.
VS2000V Veterinary Vital Signs Monitor

SPECIFICATIONS of VS2000V Monitor

Enclosure

Weight

2.05kg (4.52 lb), including 1 battery

Dimensions

324mm Wx 129mm Hx 183 mmD

(12.76in. W x 5.08in. H x 7.20in. D)

Display

Screen size

177.8 mm ( 7in.), measured diagonally

Screen type

TFT LCD, white LED backlight, viewing cone of 60°and optimal viewing distance of 1.5 meter

Resolution

800 x480 pixels

Alarms

Categories

Patient status and system status

Priorities

Low, medium, and high

Notification

Audible and visual

Setting

Full storage, low battery and sensor off

Alarm volume level

45 to 85 decibels

Alarm system delay

<10 seconds

SpO2

Aturation range

1% to 100%

Resolution

1%

Accuracy

70-100% 2%), <70% undefined

Display sweep speed

10.00 mm/sec

Pulse Rate

Aturation range

25bpm to350bpm

Resolution

1bpm

Accuracy

±2bpm/±2% take maximum

   

 

ECG

Aturation range

25bpm to350bpm

Leads

I,II,III,V,aVR,aVL or aVL

Accuracy

±2bpm/±2% take maximum

Display gain

X1/4, X1/2, X1, X2, X4

Resolution

1bpm

Display sweep speed

6.25, 12.5, 25, 50mm/sec

NIBP

Method

Oscillometric

Measurement Time

30-50s typical, 180s maximum

Aturation Range

0-300mmHg

AUTO Interval Times

2, 3, 5, 10, 30 min, or 1, 2h

Accuracy

Based on ANSI/AAMI SP10:1992 and 2002 Standards

   

RESP

Aturation range

0-130rpm

Resolution

1rpm

Accuracy

±1 pm

   

TEMP

Aturation range

0-50°C

Resolution

0.1°C

Accuracy

±0.2°C

   

ETCO2 (Optional)

Mode

Sidestream

Resolution

0.lmmHg

Aturation Range

0-150mmHg

Flow rate

50ml/min ±10ml/min

Accuracy

0-40mmHg ±2mmHg

41-150mmHg ±10% of reading

   

Electrical

Battery

Four new lithium batteries with 4,400mAh will typically provide 4.5 hours of monitoring with no external communication, no audible alarm sound, and at an ambient temperature of 25°C

Type

Lithium Batteries, 4,400mAh, DC 11.1V

Voltage

AC 100-240V, 50-60Hz, 80VA

Environmental

 

Transport and Storage

Operating Conditions

Temperature

-40°C to 75°C (-40°F to 167°F)

0°C to 50°C

(32°F to 122°F)

Altitude

-500 to 5,000m (-1,640 to 16,404 ft.)

Relative humidity

15% to 95% noncondensing

Trend

 

Tabular

Memory

Saves a total of 120 hours of data events; saves date and time, alarm conditions, measurements

Tabular format

One table for all parameters

Configuration

Standard

SpO2+ECG+NIBP+RESP+TEMP

Optional

SpO2, SpO2+NIBP, SpO2+NIBP+ECG, SpO2+NIBP+TEMP SpO2+ECG+NIBP+RESP+TEMP+ETCO2, etc.

Lithium Battery, Trolley, Brace, IPMS8600 Central monitoring system

ACCESSORIES

VS2000V Veterinary Vital Signs Monitor
Standard
VS2000V Veterinary Vital Signs Monitor
Rectal SpO2/TEMP sensors
VS2000V Veterinary Vital Signs Monitor
IPMS8600
VS2000V Veterinary Vital Signs Monitor
Trolley
VS2000V Veterinary Vital Signs Monitor
Sidestream ETCO2 Module

Other Veterinary Pulse Oximeter