Video Melting Point Meter
The melting point instrument is the material melting point instrument. Melting point material refers to the temperature at which the substance from solid to liquid, in the field of organic chemistry, melting point determination is to identify the primary means of material nature, and also is one of the essential methods for the determination of purity.
Improve Innovative Efficiency
High-definition video instead of a traditional visual microscope;
A deal with four samples;
Compatibility measurement in the shape of powder and pieces of melt(optional).
The Main Technical Indicators of JH30 & JH50
Model | JH30 | JH50 |
Temperature range | RT-350℃ | RT-400℃ |
Detection method | Semi-automatic | Semi-automatic |
Capacity per batch | 4pc. /batch | 4pc. /batch |
Temperature resolution | 0.1℃ | 0.1℃ |
Temperature gradients | (0.1-20.0) ℃/Min | (0.1-20.0) ℃/Min |
Temperature accuracy | ±0.3℃ (<250℃) | ±0.3℃(<250℃) |
±0.5℃(>250℃) | ±0.5℃ (>250℃) | |
Repeatability | ±0.1℃ (At 0.1℃ /Min) | ±0.1 ℃ (At 0.1℃ /Min) |
Exploration model | — | — |
Camera&Video | Camera | Camera&Video |
Video playback | — | YES |
Magnification | 7 | 7 |
Operator account | — | 8 |
Result storage | 200 | 400 |
SDcard capacity | 8G | 8G |
Display | TFT Touch screen | TFT Touch screen |
Interface | USB RS232 SD card Enternet | USB RS232 SD card Enternet |
Standard capillary size | I.D. 1.0mm,O.D. 1.4mm | I.D. 1.0mm,O.D. 1.4mm |
Power | 110-220V50/60HZ120W | 110-220V50/60HZ120W |
The Main Technical Indicators of JH70 JH80& JH90
Model | JH70 | JH80 | JH90 |
Temperature range | RT-350℃ | RT-400℃ | RT-420℃ |
Detection method | Fully automatic(compatible with Semi-automatic) | Fully automatic(compatible with Semi-automatic) | Fully automatic(compatible with Semi-automatic |
Capacity per batch | 4pc./batch | 4pc./batch | 4pc./batch |
Temperature resolution | 0.1℃ | 0.1℃ | 0.1℃ |
Temperature gradients | (0.1-20.0)℃/Min | (0.1-20.0)℃/Min | (0.1-20.0)℃/Min |
Temperature accuracy | ±0.3℃(<250℃) | ±0.3℃(<250℃) | ±0.3℃(<250℃) |
±0.5℃(>250℃) | ±0.5℃(>250℃) | ±0.5℃(>250℃) | |
Repeatability | ±0.1℃(At 0.1℃/Min) | ±0.1℃(At 0.1℃/Min) | ±0.1℃(At 0.1℃/Min) |
Exploration model | NO | YES | YES |
Camera & Video | Camera & Video | Camera & Video | Camera & Video |
Video playback | NO | YES | YES |
Magnification | 7 | 7 | 7 |
Operator account | 8 | 10 | 20 |
Curve storage | 10 | 20 | 80 |
Result storage | 400 | 600 | 1000 |
Method storage | — | 40 groups | 100 groups |
SD card capacity | 8G | 16G | 32G |
Display | TFT Touch screen | TFT Touch screen | TFT Touch screen |
Interface | USB RS232 SD card Enternet | USB RS232 SD card Enternet | USB RS232 SD card Enternet |
Standard capillary size | I.D. 1.0mm, O.D. 1.4mm | I.D. 1.0mm, O.D. 1.4mm | I.D. 1.0mm, O.D. 1.4mm |
Power | 110-220V50/60HZ120W | 110-220V50/60HZ120W | 110-220V50/60HZ120W |