UT100 Handheld Pulse Oximeter

The UT100 Handheld Pulse Oximeter puts pulse oximetry technology in the palm of your hand. Designed to provide fast, reliable SpO2 and pulse rate measurements. It is a portable device for spot-checking, recording, or continuous monitoring of adult, pediatric or neonate patients. It can be used in the hospital, clinical environment, homecare, and during emergency land transportation.

Features of UT100 Handheld Pulse Oximeter

  • 2.8″ high-resolution color display, two display directions.
  • Turn off automatically for power saving.
  • Two types of power supply: AC charge or 4 AA batteries.
  • Three measurement modes: spot-check, record, and monitoring.
  • 3-level visual and audio alarms with adjustable alarm ranges.
  • Continuous store data for 999 patient files in 120 hours.
  • Data can be stored on a computer and managed, analyzed, and printed by using the ODMS system.
  • Silent sleep monitoring, with data storage and automatic power-saving features for patients with 24 uninterrupted care.
  • Suitable for adults, pediatric and neonate patients.
UT100 Handheld Pulse Oximeter
Horizontal display mode with three selecting working modes.
UT100 Handheld Pulse Oximeter ODMS system
ODMS System, functional data analysis software.
UT100 Handheld Pulse Oximeter
Support free customization of multiple languages.

SPECIFICATIONS of UT100 Handheld Pulse Oximeter

Enclosure

Weight

258g (0.569 lb), including four batteries

Dimensions

75mmWx 135mmH x28mmD

(2.95 in. Wx531 in. H x1.10in. D)


Display

Screen size

71.1 mm (2.8 in.), measured diagonally

Screen type

TFT LCD, white LED backlight, viewing cone of 60°and optimal viewing distance of 1 meter

Resolution

240×320 pixels

Alarms

Categories

Patient status and system status

Priorities

Low, medium, and high

Notification

Audible and visual

Setting

Full storage, low battery and sensoroff

Alarm volume level

45 to 85 decibels

Alarm system delay

<10seconds

SpO2

Aturation range

1% to100%

Accuracy

70-100%±2%), <70%undefined

Resolution

1%

Display sweep speed

10.00 mm/sec

Pulse Rate

Aturation range

25bpm to250bpm

Accuracy

±2bpm/±2% take maximum

Resolution

1bpm

Electrical

Battery

Four new Ni-Mh batteries with 4,800mAhwilltypically provide 20 hours of monitoring with no external communication, no audible alarm sound, and at an ambient temperature of 2 5°C

Type

Alkaline/Ni-Mh Batteries, IEC: LR6

Voltage

1.5 Vx4 for Alkaline Batteries, 1.2V x4 for Ni-Mh Batteries

Environment


Transport and Storage

Operating Conditions

Temperature

-20°C to 60°C

(-4°F to 140°F)

0°C to 45°C (32°F to 113°F)

Altitude

-500 to 5,000m(-1,640 to 16,404 ft.)

Relative humidity

15%to95%noncondensing

Trend

Tabular

Memory

Saves a total of 120 hours of data events; saves date and time, alarm conditions, pulse rate, and SpO2measurements

Tabular format

One table for all parameters

Configuration

Standard

Adult finger dip SpO2 sensor, Hanging Strip

Optional

Neonate SpO2 sensor, Pediatric SpO2 sensor, Various SpO2 sensors(ear clip, disposable, silicone soft tip, etc), AC adapter, Alkaline/Ni-Mh Batteries, Protective Cover, Data Analysis Software

ACCESSORIES

accessories of UT100 Handheld Pulse Oximeter
Disposable SpO2 sensor
accessories of UT100 Handheld Pulse Oximeter
Neonate SpO2 sensor
accessories of UT100 Handheld Pulse Oximeter
Protective Cover
accessories of UT100 Handheld Pulse Oximeter
accessories of UT100 Handheld Pulse Oximeter
Pediatric SpO2 sensor
accessories of UT100 Handheld Pulse Oximeter
Silicone soft SpO2 sensor
accessories of UT100 Handheld Pulse Oximeter
AC Adapter