uPM60V Veterinary Pulse Oximeter
The uPM60V Veterinary Pulse Oximeter is a low cost monitor for spot checking, continuous, noninvasive monitoring, or recording of functional oxygen saturation of arterial SpO2, pulse rate, and pulse strength. It may be used in the veterinary hospital or clinical environment. The oximeter works with given sensors providing SpO2 and pulse rate on a variety of veterinaries like horses, dogs, cats, etc with adjustable alarm limits as well as visible and audible alarm signals.
Features of uPM60V Veterinary Pulse Oximeter:
- 3.5’Large size color touch screen(optional),320X480pixels.
- Turn off automatically for power saving.
- Uses a Lithium battery.
- Three measurement modes: spot-check, monitoring, and record.
- Continuous storage of data for 999 patient data in 120 hours.
- Data can be stored on a computer and managed, analyzed, and printed by using the ODMS system.
- Silent sleep monitoring, with data storage and automatic power-saving features for patients with 24 hours of uninterrupted care.
- Expanded heart rate values and veterinary specific SpO2 sensors to accommodate a variety of species.
SPECIFICATIONS of uPM60V Veterinary Pulse Oximeter
Enclosure
Weight |
280g(0.617lb)with batteries |
Dimensions |
78.5mmWx158mmHx31.5mmD (3.09in.Wx6.22in.Hx1.24in.D) |
Display |
|
Screen size |
88.9mm(3.5′),measured diagonally |
Screentype |
TFT LCD, white LED backlight |
Resolution |
320x480pixels |
Alarms |
|
Categories |
Patient status and system status |
Priorities |
Low,medium,and high |
Notification |
Audible and visual |
Setting |
Fullstorage,low battery and sensor off |
Alarmvolumelevel |
45 to 85 decibels |
Alarmsystemdelay |
<10seconds |
SpO2
Measurement range |
1% to 100% |
Resolution |
1% |
Accuracy |
70-100% (±2%), <70% undefined |
Display wave speed |
10.00 mm/sec |
Pulse Rate
PR range |
30bpm to 400bpm |
Accuracy |
±2bpm/±2% take maximum |
Resolution |
1bpm |
Electrical
Battery |
Lithium battery with 4,400mAh will typically provide 15 hours of monitoring with no external communication, no audible alarm sound. |
Type |
Lithium Battery |
Voltage |
3.7V |
Environmental
Battery |
Lithium battery with 4,400mAh will typically provide 15 hours of monitoring with no external communication, no audible alarm sound. |
Type |
Lithium Battery |
Voltage |
3.7V |
Trend
Tabular |
|
Memory |
Saves a total of 120hours of data events; saves date and time, alarm conditions, measurements |
Tabular format |
One table for all parameters |
Configuration
Standard |
Main unit,VeterinarySpO2 sensor, Charging base, Lithium Battery |
Optional Configuration |
Data Analysis Software(ODMS), Touch Screen |