uPM60C Vital Signs Monitor
The uPM60C Vital Signs Monitor is a low-cost monitor for spot checking, continuous, non-invasive monitoring, or recording of functional oxygen saturation of arterial hemoglobin (SpO2), pulse rate, pulse strength, end-tidal CO2, FiCO2, and Respiration Rate. The monitor is a 4400mAh lithium battery and Type-C adapter-powered device. It may be used in the hospital, clinical environment, homecare, and during emergency land transportation.
Features of uPM60C Vital Signs Monitor
- 3.5′ Large size color touchscreen (optional), 320X480 pixels.
- Two types of power supply: AC charger or 4400mAh Lithium battery.
- Three measurement modes: spot-check, monitoring, and record.
- Continuous storage of data for 999 patient data in 120 hours.
- Capnograph with trends and SpO2 with waveform.
- Different types of patients provide different alarm limits default values.
- Silent sleep monitoring , with data storage and automatic power-saving features for patients with 24 uninterrupted care.
- Suitable for adults, pediatric and neonate patients.
SPECIFICATIONS of uPM60C Vital Signs Monitor
Enclosure
Weight |
280g(0.617lb) with batteries |
Dimensions |
78.5mmW x 158mmH x 31.5mmD (3.09in.W x 6.22in.H x 1.24in.D) |
Display |
|
Screen size |
88.9mm (3.5in.), measured diagonally |
Screen type |
TFT LCD, white LED backlight |
Resolution |
320×480 pixels |
Alarms |
|
Categories |
Patient status and system status |
Priorities |
Low, medium, and high |
Notification |
Audible and visual |
Setting |
Fullstorage, low battery and sensor off |
Alarm volume level |
45 to 85 decibels |
Alarm system delay |
<10 seconds |
SpO2
Measurement range |
1% to 100% |
Accuracy |
70-100% (±2%), <70% undefined |
Resolution |
1% |
Displaywave speed |
10.00mm/sec |
Trend
Tabular |
|
Memory |
Saves a total of 120 hours of data events; saves date and time, alarm conditions, measurements |
Tabular format |
One table for all parameters |
ECTO2
Mode |
Sidestream or Mainstream |
Aturation Range |
0-150mmHg |
Accuracy |
0-40mmHg±2mmHg 41-150mmHg±10% of reading |
Resolution |
0.1mmHg |
Flow Rate |
50ml/min±10ml/min |
PulseRate
PR range |
25bpm to 250bpm |
Accuracy |
±2bpm / ±2% take maximum |
Resolution |
1bpm |
Electrical
Battery |
Lithium battery with 4,400mAh will typically provide 15 hours of monitoring with no external communication, no audible alarm sound |
Type |
Lithium Battery |
Voltage |
3.7V |
Environmental
Transport and Storage |
OperatingConditions |
|
Temperature |
−20ºC to 60ºC (−4ºF to 140ºF) |
0ºC to 45ºC (32ºF to 113ºF) |
Altitude |
−500 to 5,000m (−1,640 to 16,404 ft.) |
|
Relative humidity |
15% to 95%x non condensing |
Configuration
Standard |
Adult finger clip SpO2 sensor, Main uint, Base, Mainstream ETCO2 Sensor |
Optional |
Adult finger clip SpO2 sensor, Main uint Neonate SpO2 sensor, Pediatric SpO2 sensor, Various SpO2 sensors (earclip, disposable, silicone softtip, etc), AC Adapter/Data Analysis Software, Sidestream sensor |