uPM60 Pulse Oximeter

The uPM60 is a Pulse Oximeter included in pulse oximetry and pulse rate technology. Designed to provide fast, reliable SpO2, and PR measurements. It is a portable device for spot-checking, and monitoring adult, pediatric and neonate patients. It can be used in the hospital, clinical environment, home healthcare, and during emergencies and transportation.

Features of uPM60 Pulse Oximeter

  • 3.5’Large size color touchscreen,320X480pixels.
  • Two types of power supply: AC charger or 4400mAh Lithium-lon Battery.
  • Three measurement modes: spot-check, monitoring, and record.
  • Continuous storage of data for 999 patient data in 120 hours.
  • Data can be stored on a computer and managed, analyzed, and printed with a data analysis system.
  • Silent sleep monitoring, with data storage and automatic power-saving features for patients with 24 uninterrupted care.
  • Suitable for adults, pediatric and neonate patients.

SPECIFICATIONS of uPM60 Pulse Oximeter

Enclosure

Weight

280g(0.617lb)with batteries

Dimensions

78.5mmWx158mmHx31.5mmD (3.09in.Wx6.22in.Hx1.24in.D)

Display

Screen size

88.9mm(3.5in.),measured diagonally

Screen type

TFTLCD, white LED backlight

Resolution

320x480pixels

Alarms

Categories

Patient status and system status

Priorities

Low,medium,and high

Notification

Audible and visual

Setting

Full storage,low battery and sensor off

Alarm volume level

45 to 85 decibels

Alarm system delay

<10seconds

SpO2

Measurementrange

1% to 100%

Accuracy

70-100% (±2%), <70% undefined

Resolution

1%

Display wave speed

10.00 mm/sec

Pulse Rate

PR range

25bpm to 250bpm

Accuracy

±2bpm/±2% take maximum

Resolution

1bpm

Electrical

Battery

Lithium-lon batteries with 4,400mAh will typically provide

24 hours of monitoring with no external communication,

no audible alarm sound.

Type

Lithium-lon Battery

Voltage

3.7V

Environmental

Transport and Storage

Operating Conditions

Temperature

−20 ºC to 60 ºC

(−4 ºF to 140 ºF)

0 ºC to 45 ºC

(32 ºF to 113 ºF)

Altitude

−500 to 5,000m (−1,640 to 16,404 ft.)

Relative humidity

15% to 95%x non condensing

Configuration

Standard

Adult finger clip SpO2 sensor, Main uint

Optional

Adult finger clip SpO2 sensor, Main uint Neonate SpO2 sensor,Pediatric SpO2 sensor, Various SpO2 sensors (earclip,disposable, silicone softtip, etc), Protective Cover/AC Adapter/Data Analysis Software

Trend

Tabular Memory Saves a total of 120hours of data events; saves date and time, alarm conditions, measurements Tabular format One table for all parameters

Other Patient Monitor