TDL-6MX Intelligent Benchtop Low Speed Refrigerated Centrifuge
TDL-6MX intelligent centrifuge, LCD digital touch display, stable operation and precise timing. It can be used in biological laboratory, medical, biological, research, PCR, life science etc.
Features of Refrigerated Centrifuge TDL-6MX
- Microprocessor control, speed control by frequency-conversion and CFC compressor.Maintenance free Frequency-conversion motor without carbon dust pollution.
- Advanced door lid control system can both electric control open and close door lid, also equipped with emergency lid lock release to avoid power off unexpected.
- 10 programs can be stored, quickly recall the last used program.
- Automatic rotor identification to avoid over speed running by mistake operate.
- Easy operation, 7 inches LCD touch panel, shows all parameters in screen.
- With Emergency lid lock release, in case of power off.
- Error minder for wrong operate or problem.
Technical Parameters of Refrigerated Centrifuge TDL-6MX
Model | TDL-6MX | Speed Accuracy | ±50r/min |
Max Speed | 6000r/min | Timer Range | 0~99min |
Max RCF | 5600xg | Temp Range | -20℃~﹢40℃ |
Display | LCD Touch display | Max Capacity | 4×250ml |
Noise | ≤60dB(A) | Power Supply | AC220v&110V 50Hz 18A |
Weight | 85kg | Dimension | 720x500x420mm |
Rotors of Refrigerated Centrifuge TDL-6MX
No.1 AR | Max Speed:6000r/min | No.2 SR | Max Speed:4000r/min | ||
Capacity:12×15/10ml | Capacity:24×10/15ml | ||||
Max RCF:5600xg | Max RCF:3020xg | ||||
No.3 SR | Max Speed:4000r/min | No.4 SR | Max Speed:4000r/min | ||
Capacity:32×10/15ml | Capacity:4/8×50ml | ||||
Max RCF:3020xg | Max RCF:3020xg | ||||
No.5 SR | Max Speed:4000r/min | No.6 SR | Max Speed:4000r/min | ||
Capacity:72×2/5ml | Capacity:48×5ml | ||||
Max RCF:3020xg | Max RCF:3000xg | ||||
No.7 SR | Max Speed:4000r/min | No.8 SR | Max Speed:4000r/min | ||
Capacity:4/8×100ml | Capacity:4×250ml | ||||
Max RCF:3020xg | Max RCF:3300xg | ||||
No.9 SR | Max Speed:4000r/min | No.10 MTP | Max Speed:3000r/min | ||
Capacity:48×10/15ml | Capacity:2x2x96holes | ||||
Max RCF:3020xg | Max RCF:2300xg |
Note: Rotors can be customized