Automatic Refractometer

Automatic refractometers are precision instruments used to measure the refractive index of liquids. The refractive index is a property that depends on the concentration and composition of a substance. Drawell refractometers offer high accuracy and speed, making them valuable tools for quality control, research, and analysis in industries like food and beverage, pharmaceuticals, and chemicals. They are often used to determine the concentration of solutes in solutions, measure sugar content in beverages, and assess the purity of chemicals.

Features of Automatic Refractometer

  1. FTF color touch screen, easy to operate.
  2. High precision and accuracy.
  3. Low cost of analysis.
  4. Wide range of uses.
Automatic Refractometer
application of Automatic Refractometer

Applications of Automatic Refractometer

Automatic refractometers have been widely used in the petroleum industry, pharmaceutical industry, food industry, daily chemical industry, sugar industry, etc, it is one of the schools and the relevant scientific research units of commonly used equipment.

How to Choose a Suitable Refractometer?

  1. Automatic refractometer or Abbe refractometer?
    First of all, the automatic refractometer can test liquids, and the Abbe refractometer can measure both solids and liquids. Secondly, the Abbe refractometer has certain requirements for measuring liquids, such as viscous and dark samples, which will reduce its measurement accuracy, while the full Autorefractometers do not have these concerns.
  2. Does it need temperature control to test the refractive index?
    The degree will affect the refractive index of the substance, and the effect of temperature on different substances is different, the temperature deviation of the same substance is not linear, only a few substances have a temperature deviation coefficient or a temperature deviation table, and most of them have a temperature deviation coefficient or a temperature deviation table. Substance testing needs to be measured at the specified temperature.
  3. What are the advantages of built-in temperature control?
    Compared with the external water bath, the Built-in Peltier temperature control has the advantages of small temperature control volume and fast speed. It is built into the instrument and it is more convenient for users to set various test requirements, avoiding errors or mistakes caused when multiple instruments work together.

Why Choose US?

1. JH series and DigiPol-R series meet different user needs.

The classic and economical JH series is suitable for most user needs; the DigiPol-R series meets 21 CFR PART 11, and has the function of audit trail electronic signature, etc., to meet the higher needs of users.

2. Multiple models can be selected

Users can choose whether to want the temperature control function, and different precisions can meet different needs of users.

3. Professional engineering team to solve your pre-sales and after-sales problems.

FAQ

– We are a factory.

  • Usually, MOQ is 1 piece.
  • The general MOQ differs greatly between different products if there is no stock. But the quantity still can be negotiated.

– Sample is available, but we do not provide free samples.

– OEM service is available with customer’s brand.

– We accept the payment by L/C, T/T, Paypal, Western Union, etc.

– Generally, it will take 7-15 working days after receiving your advance payment. Depend on the quantity.

– We could provide Online instruction; Real-time support by video call or voice chat; During warranty time, we can send product accessories when you need them for free; Technical guidance is free and ready forever.

– 1 year. it can be negotiated if you need an extended warranty.

– Email: sales08@drawell.com.cn

– Tel.: 008613320353102

Related Products Recommendation