PM6800 Patient Monitor

  • PM6800 Patient Monitor: 15’’large-sized screen, anti-dazzle with 4 incline 
  • Large measurement rangers of SpO2,  Pulse Rate, ECG, RESP, TEMP, NIBP, ETCO2 technical specialized   
  • Printer and IBP optional 
  • Suitable for Adult, Pediatric, and Neonate Use  
  • Support3lead/5 lead ECG  
  • Free to Choose Mainstream and Sidestream ETCO2 sensor 
  • SupportingArrhythmia detection. 
PM6800 Patient Monitor
Large sized 15  inch display, antidazzle with 4incline and with colorful button.
PM6800 Patient Monitor
Ergonomically designed handle to fit your hand comfortably
PM6800 Patient Monitor
The convenient battery Compartment design You can get by yourself 
PM6800 Patient Monitor
Free to Choose Mainstream and Side stream ETCO2 sensor

SPECIFICATIONS of PM6800 Patient Monitor

ECG

Lead selection

I,II,III,V,AVF,AVL,AVR 

Heart rate range

30-350 BPM

ECG waveform

1 or3Channels

Accuracy

±2 BPM or ±2% (whichever is greater)

Gain selection

0.25,0.5,1,2 and 4(mm/mv),auto

Resolution

1BPM

Sweep speed 

6.25 mm/s,12.5mm/s, 25mm/s,50mm/s

S-T deletion

Yes

SpO2

(SpO2) measuring range

0-100%

(PR measuring accuracy

±2%

(Sp02) measuring accuracy

70  100% (±2%)

<70% undefined

(PR) Resolution

1bpm

(SpO2) Resolution

1%

(PR) Alarm limit

High 50%-100%, Off

Low 50%-100%,Off

(PR) measuring range

20-400 bpm

   

NIBP

Technical

Oscillometric during inflation

Range of Diastolic

20 to 200 mmHg

Range of Systolic

40 to 270 mmHg

Measuring time

30 to 50 seconds typical,

120 seconds maximum

Range of Mean Arterial

30 to 220 mmHg

Alarm range

20-260(in 1 mmHgsteps),and OFF

IBP (optional)

Respiration

Measuring range

0-120rpm

Measuring range

25-45℃

Resolution

1rpm

Resolution

0.1℃

Accuracy

±1rpm

Accuracy

±0.2℃, plus the temperature

sensor tolerance

ETCO2 (External end-tidal mainstream / sidestream CO2 ) Optional

Measuring range

0-150mmHg

Accuracy 

± 2mmHg (0-40)mmHg

±5mmHg(41-70)mmHg

± 8mmHg (71-100)mmHg

± 10mmHg (101-150)mmHg

Resolution

0.1mmHg (0-69)mmHg

0.25mmHg (70-150)mmHg

Printer (optional)

Type

Thermal line printer

Paper Speed

12.5, 25, 50 mm/sec

Display

Screen

15″ active color TFT

Waveforms

6,maximum

Resolution

1024 x 768 pixels

WaveformTypes

ECGleadsI, II, III, aVR, aVL, aVF, V; Respiration; Pleth; ST Histograms

Physical Properties

Weight

6.5kg

Size

363cm (L) x 339cm (W) x 19cm (H)

Environmental

Operating Temperature

15℃-35℃

Operating Humidity

15% to 90%, noncondensing

Storage Temperature

– 5℃-50℃

   

Other Patient Monitor