PCD100T Benchtop pH/mV/Cond/DO Meter – Touch Screen

PCD100T benchtop pH/mV/Cond/DO Meter(Multi-parameter Meter)can simultaneously measure the pH, conductivity, temperature and dissolved oxygen altogether. It is a multifunctional touch-screen machine.

It can used for soil measurements in agriculture, water quality for municipal water supplies, environmental remediation, pharmaceuticals, food, industry, electric power, scientific research, etc.

Features of PCD100T Benchtop pH/mV/Cond/DO Meter

  1. With built-in microprocessor chip, intelligent and high accuracy.
  2. 7″ TFT Touch screen, easy reading and operation.
  3. With calibration guide, automatic calibration, automatic temperature compensation, data storage, parameter setup, etc.
  4. Self-diagnosis functions, automatically recognizing standard buffer solutions.
  5. Cal points: pH calibration points: 1-5 pts; Cond: 1 pt. DO: 100% Oxygen or Zero oxygen calibration.
  6. Fast response, stable reading display.
  7. The kit comes with a combination glass electrode, stainless steel temp probe, and an ATC glass cond. probe.
  8. IP54 dustproof and spillproof.
Meter-touch-Screen
PCD100T accessory

Specifications of PCD100T Benchtop pH/mV/Cond/DO Meter

pHRange(-2.000-20.000) pH
Resolution0.001/0.01 pH
Accuracy±0.002pH ±1digit
Cond.Range0~2000.0mS/cm, auto divided by range of:
0~19.999μS/cm; 20.0~199.9μS/cm; 200~1999μS/cm;
2.00~19.99mS/cm; 20.00~199.9mS/cm;
200.0~2000mS/cm(K=10)the match test: 0-200.0mS/cm
Resolution0.001
Accuracy±0.5 % FS±1digit
DORange  0-20.00 mg/L(ppm), 0-200.0 %
Accuracy/Resolution± 0.30 mg/L;0.01 or 0.1 mg/L
ATC range(0 – 50)℃ automatically
Salinity compensation0~45 ppt manual
Barometric compensation0~200 kPa automatically
mV(ORP probe optional)Range-1,999mV -+1,999mV
Resolution± 0.1/1mV
Accuracy±0.03% FS ±1digit
TemperatureRange0-100°C
Resolution/Accuracy0.1℃; ±0.2℃
Data storage1500groups
Data OutputUSB to Flash DiskUSB to PCWireless connection to printer (the printer is optional)
Power supplyDC12V
Packing includingPCD100T Meter
201G Refillable glass pH probe: 1pc
Temp-01 Stainless steel probe: 1pc
pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each
CON201TG Glass ATC Cond probe, (K=1)
Standard Cond solution: 50mL: 84μS/1413μS/12.88mS/cm, one for each
DO01-2M Polarographic DO probe, cable length: 2m
DOS-01 Membrane refill solution: 30mL,1pc
DOSC Sensor caps: 3pcs/group, 1pkg
F01 Flexible probe holder: 1pc
Magnetic stirrer: 1pc
PC cable: 1pc
A01 Power adaptor

Touch-screen Benchtop PH Meter1
Touch-screen Benchtop PH Meter2
Touch-screen Benchtop PH Meter3