Oil Melting Point Instrument Series

Automatic oil automatic precise measuring instrument for melting various oil product melting points, good navigation mechanical grease instrument of melting the perfect combination of high precision Peltier temperature control technology and high-definition video camera technology, not only provides the test result is accurate, stable, and reliable for users, but also bring the test experience efficient and convenient for users. Peltier temperature control technology can realize high precision temperature control,high-definition video can conveniently and clearly see the whole process of sample melting, automatic detection to eliminate the subjective error to determine the melting point, reducing the labor intensity of the staff, convenience for the user to measure the melting point of the sample accurately.

The Main Technical Indicators of JHY30 & JHY50

Model JHY30 JHY50
Temperature control range RT-100 6-100
Detection method Semi-automatic Semi-automatic
Capacity per batch 2pc./batch 2pc./batch
Temperature resolution 0.1 0.1
Temperature gradients (0.1-10.0)/Min (0.1-10.0)/Min
Temperature accuracy ±0.3 ±0.3
Repeatability 0.1/Min时±0.1 0.1/Min时±0.1
Camera&Video Camera Camera&Video
Video playback YES
Operator account 8
Result storage 200 400
SD card capacity 8G 8G
Display TFT Touch screen TFT Touch screen
Interface USB RS232 SD card Enternet USB RS232 SD card Enternet
Opening capillary size I.D>1.0mm,O.D.1.4mm I.D>1.0mm,O.D.1.4mm
Double opening Double opening
Power 110-220V 50/60HZ 120W 110-220V 50/60HZ 120W

1: Paltier precise temperature function;
2: a key automatic detection function;
3: in line with the international and ISO in the determination of the melting point of oils and fats.

The Main Technical Indicators of JHY70 & JHY90

Model JHY70 JHY90
Temperature control range RT-100 4-100°
Detection method Fully automatic(compatible with Semi-automatic) Fully automatic(compatible with Semi-automatic)
Capacity per batch 2pc./batch 2pc./batch
Temperature resolution 0.1 0.1
Temperature gradients (0.1-10.0)/Min (0.1-10.0)/Min
Temperature accuracy ±0.3 ±0.3
Repeatability 0.1/Min时±0.1 0.1/Min时±0.1
Camera&Video Camera Camera&Video
Video playback NO YES
Operator account 10 20
Result storage 600 1000
SD card capacity 8G 16G
Display TFT Touch screen TFT Touch screen
Interface USB RS232 SD card Enternet USB RS232 SD card Enternet
Opening capillary size I.D.1.0mm,O.D.1.4mm I.D.1.0mm,O.D.1.4mm
Power 110-220V 50/60HZ 120W 110-220V 50/60HZ 120W

Standard:SNT0801.5-2015、GB/T24892-2010、GBT12766-2008

Use filed

Chemical, pharmaceutical, supervision, food and drug administration, and quarantine, are widely applied in colleges and universities and other related departments. Melting point is an important feature of the material, material research is of great significance. Is the production of medicines, spices, dye, and other organic crystal substances essential equipment.

Automatic melting point meter

Related Point Meter Recommendation