NIR DW-EXPEC1330 Near Infrared Spectroscopy Analysis Technology
The DW-EXPEC1330 instrument is easy to operate, non-destructive and fast. Just pour the sample into the sample cup and place it on the rotating test table for measurement. After 3 seconds, we can get the multi-component index (such as moisture, crude protein, oil content, etc.) detection data. The analyzer is small in size and optional rechargeable battery, which makes it easy to carry around for on-site testing, especially suitable for rapid judgment of sample quality at the acquisition site.
Features of NIR DW-EXPEC1330 Near Infrared Spectroscopy Analysis Technology
- Removable
- Fast analysis, results within 3 seconds
- Start Sample detection after 5 minutes of warm-up
- Optional rechargeable battery, power supply over 8 hours
- Sample without crushing, direct detection
- Sample loading is easy and fast, pour the sample into the sample cup, and it can be detected when it exceeds half the height of the cup
- Simultaneous detection of multiple quality indicators: such as moisture, crude protein, oil content, etc.
- Daily detection without consumables
- Low power consumption, power less than 25W
- Suitable for a variety of sample states, such as granules, strips and powders
- High accuracy of analysis results
- Analysis results can be calibrated using standard samples
Specifications of NIR DW-EXPEC1330 Near Infrared Spectroscopy Analysis Technology
Instrument size (L*W*H) | (300x 220x 310) mm |
Weight | About 10kg (without batteries) |
Analysis sample | Grain |
Sample status | Granules, powders and strip solids |
Sample capacity | About 200ml |
Detection form | Diffuse reflection |
Light source | Tungsten halide lamp |
Light source power | 5V 10W |
Detector | TEC refrigerated and temperature-controlled indium gallium arsenide (InGaAs) detector |
Preheating time | 5 minutes |
Power supply | DC 12V adapter or DC 24V adapter (for use with batteries) |
Expansion connection | USB2.0 or Bluetooth |
Ambient temperature | (5-40)℃ |
Ambient humidity | (5%-85%) RH, no condensation |
Wavelength range | 1000-1800nm |
Absorbance noise | <50uA |
Wavelength accuracy | ±0.2nm |
Wavelength repeatability | < 0.01 nm |
Spectral resolution | ( 10.95±0.3) [email protected] |
Stray light | < 0.15% |
Applications of NIR DW-EXPEC1330 Near Infrared Spectroscopy Analysis Technology