Micro High Speed Refrigerated Centrifuge TGL-18/iTGL-18

  1. Stainless steel chamber, compact structure, can can use 8 different capacity rotors.
  2. Safety Interlock system that prevents opening the centrifuge lid during running.
  3. 10 programs can be stored, quickly recall the last used program.
  4. Imbalance sensor, Over speed and over temperature cut off
  5. Easy operation, LCD touch screen, compressor control.
  6. Accurate temperature control, range from -20℃~+40℃
  7. With Emergency lid lock release, in case of power off.

Functions of Micro High Speed Refrigerated Centrifuge TGL-18/iTGL-18

iTGL-18 high speed refrigerated centrifuge is useful for routine application in bio-technology, PCR, life science and clinical labs etc. This is suitable for routine sample analysis in Medical, Hospital and Institutional laboratories. With a wide choice of rotor heads and adapters, this unit is truly versatile.

Micro High Speed Refrigerated Centrifuge TGL-18iTGL-18 Rotor
Micro High Speed Refrigerated Centrifuge TGL-18

Parameters of Micro High Speed Refrigerated Centrifuge TGL-18/iTGL-18

ModelTGL-18 (LCD Display)iTGL-18 (Touch LCD Display)
Max Speed18500r/mi Â±10r/minTimer Range0~99min
Max RCF19920xgMotorConvert motor
DisplayLCD touch displayNoise≤60dB(A)
Max Capacity36 x1.5/2mlPower SupplyAC220v&110V 50Hz 18A
Temperature Range-20℃~+40℃Dimension540x340x312mm(L*W*H)
Temperature Accuracy±1℃Weight40kg

Rotors of Micro High Speed Refrigerated Centrifuge TGL-18/iTGL-18

Note: rotors can be customized

TGL 16 rotor1No.1Max Speed:18500r/min
Capacity:12×0.5ml AR
Max RCF:19920xg
TGL 16 rotor1No.2 Max Speed:16000r/min
Capacity:12×1.5/2ml AR
Max RCF:17800xg
Micro High Speed Refrigerated Centrifuge RotorNo.3Max Speed:14000r/min
Capacity:24×1.5/2ml AR
Max RCF:18860xg
Micro High Speed Refrigerated Centrifuge Rotor-2No.4Max Speed:16000r/min
Capacity:2×8×0.2ml PCR tube
Max RCF:15450xg
Micro High Speed Refrigerated Centrifuge Rotor-3No.5Max Speed:11000r/min
Capacity:36×1.5/2ml AR
Max RCF:10800xg
Micro High Speed Refrigerated Centrifuge Rotor-4No.6Max Speed:16000r/min
Capacity:18×0.5ml AR
Max RCF:15450xg
Micro High Speed Refrigerated Centrifuge Rotor-5No.7Max Speed:12000r/min
Capacity:12/10/8×5ml AR
Max RCF:10560xg
Micro High Speed Refrigerated Centrifuge Rotor-6No.8Max Speed:12000r/min
Capacity:48×0.5ml
Max RCF:11060xg
Micro High Speed Refrigerated Centrifuge Rotor-7No.9Max Speed:15000r/min
Capacity:3×8×0.2ml PCR tube
Max RCF:14750xg
Micro High Speed Refrigerated Centrifuge Rotor-8No.10Max Speed:13500r/min
Capacity:4×8×0.2ml PCR tube
Max RCF:11610xg