MHVS-5/10/30/50AT Digital Vickers Hardness Tester
Characteristics:
- High precision step-controlled electric loading technology, the main test force loading speed is very fast and efficiency is improved.
- New mechanical structure design, strong frame structure
- Real-time measurement, better effect, more accurate and more stable
- The data of operation process and test results can be displayed on the screen.
- The light source can be measured by adjusting the screen.
- Measuring indentation is more stable
- Automatic Conversion of Pressure Head and Object Lens
- Can preset the test force guarantee time
- The experimental data can be output by printer.
Characteristics of Control System
- High Precision Step Control Electric Loading Technology
- Ultra-high test force accuracy: test force loading and retaining accuracy reaches 10,000 grades
- The loading speed of the main test force is very fast and the efficiency is improved.
- High Precision Sensor Cooperating with Control System
- The Unique Value Curve
- Loading and unloading speed is faster and more accurate
- The remote control can be realized and the operation is simple.
- Extremely Fast Loading Speed: Loading Time of Test Force 2-6 seconds
- Intelligent control of the whole process. Sectional force application, smooth speed change, high precision and high speed step control, etc.
Technical Parameters of MHVS-5/10/30/50AT Vickers Hardness Tester
Model | MHVS-5AT | MHVS-10AT | MHVS-30AT | MHVS-50AT | ||||
Test force(kgf) | 0.2、0.3、0.5、1、2、3、5 | 0.3、0.5、1、2、3、5、10 | 0.5、1、2、3、5、10、20、30 | 1、2、3、5、10、20、30、50 | ||||
Loading method | Automatic loading and unloading | |||||||
Test Force Switching | Automatic | |||||||
Language selection | Chinese, English | |||||||
Duration time | 5-60s | |||||||
Indenter and Object Lens Switching | manual | automatic | manual | automatic | manual | automatic | manual | automatic |
Testable parameters | HV\HK | |||||||
Objective lense | 10X、20X | |||||||
Digital Encoder Micrometer Eyepiece | 10X | |||||||
Maximum measuring length | 400μm | |||||||
Minimum graduation | 0.1μm | |||||||
Maximum height of sample | 100mm | |||||||
Maximum depth of sample | 100mm | |||||||
Hardness Conversion | HRA、HRB、HRC、HR15N、HR30N、HR45N、HR15T、HR30T、HR45T、HK、HBW | |||||||
Touch screen operation panel | Force Curve, Options, Database, Control, Loading Start, Lighting Adjustment, Object Switching | |||||||
Value Display | D1, D2 value, HV indication, hardness value, conversion value, shelf life, test times | |||||||
light source | 5V/3W | |||||||
communication interface | RS 232 | |||||||
Executive standard | JJG151-2006,GB/T 4340, ISO/DIN6507,ASTM E-384 | |||||||
Power supply | AC90-240V,50-60Hz | |||||||
Shape size | 510*180*550mm | |||||||
Machine net weight | About 45kg |