M600L Multi-parameter Analyzer
- Color High contrast LCD touchscreen, 7.0 inches.
- Intelligent operation system provides features including user management, calibration management, method management, data management and etc.
- Multi-reading feature allows auto-read, timed-read and continuous-read.
- Automatic/Manual temperature compensation ensures accurate results.
- Data Storage 1000 sets for each parameter (GLP-compliant).
- Data analysis feature helps user review, compare and recalculate results.
- Support for USB or RS-232 communication.
- Reset feature automatically resumes all settings back to factory default options.
- IP54 waterproof.
- Support for three modules, namely pH/ISE module, conductivity module and dissolved oxygen module.
- Select from three modules to customize the four channels your way.
- Four channels can be configured in any combination.
Features of M600L Multi-parameter Analyzer
pH
- 1-6 points calibration with Standard Recognition.
- Selectable pH buffer groups, including NIST, DIN, GB.
- Support for pH standard group customization.
- Automatic electrode diagnosis with pH slope and offset display.
Ion
- 1-6 points calibration
- Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, etc.
- Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
- Over 10 methods are built-in, including F–, Cl–, Br–, I–, NO3–, BF4–, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.
Conductivity
- 1-5 points calibration with Standard Recognition.
- Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.
- Temperature compensation type (none, linear, pure water).
DO
- Support for air-saturated water or zero oxygen calibration.
- Auto barometric pressure compensation.
- Manual Salinity Factor Correction.
- Selectable pressure unit, including kPa, mbar, Torr, Atm.
Includes
- E-201-L pH composite electrode
- PF-202-L Fluoride ion selective electrode
- DJS-1-LEC electrode
- T-818-L Temperature probe
- DO-958-L DO electrode
- NIST pH standard solution(4.01, 7.00, 10.01) , 50ml/vial
- 1413μS/cm EC standard solution, 50ml, 1 vial
- REX-3 electrode stand
- Touch pen
Specifications of M600L Multi-parameter Analyzer
Model | M600L | |
Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
pH | Range | -2.000 to 20.000 pH |
Resolution | 0.1, 0.01, 0.001pH | |
Accuracy | ±0.002 pH | |
Calibration Points | Up to 6 | |
Standard Customization | Yes | |
Calibration Reminder | Yes | |
Standard Recognition | NIST, GB, DIN buffers | |
Slope Limit | Yes | |
mV/ORP | Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV | |
Accuracy | ±0.03%FS | |
EH ORP Mode | Yes | |
ORP Calibration Points | 1~2 custom point (relative mV) | |
pX | Range | -2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX | |
Accuracy | ±0.002 pX | |
Calibration Points | Up to 6 | |
ISE | Range | 1.000e-9 to 9.999e+9 |
Units | mol/L, mmol/L, g/L, mg/L, μg/L | |
Resolution | Up to 4 significant digits | |
Accuracy | ±0.3% | |
Calibration Points | Up to 6 | |
Conductivity | Range | 0.000 μS/cm to 3000 mS/cm |
Resolution | 0.001 μS/cm minimum, various with range selection | |
Accuracy | ±0.5% FS | |
Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
Calibration Points | Up to 5 | |
Standard Recognition | 146.5μS/cm, 1408μS/cm, 12.85mS/cm, 111.3mS/cm | |
Resistivity | Range | 5.00 Ω·cm~100.0 MΩ·cm |
Resolution | 0.01 Ω·cm minimum | |
Accuracy | ±0.5% FS | |
TDS | Range | 0.000 mg/L~1000 g/L |
Resolution | 0.001ppm minimum, changed with range | |
Accuracy | ±0.5% FS | |
Salinity | Type | NaCl% |
Range | (0.00~8.00)% | |
Resolution | 0.01% | |
Accuracy | ±0.1% | |
Dissolved | Range | 0.00 to 99.99 mg/L |
Oxygen Concentration – Polarographic | Resolution | 0.01 mg/L |
Accuracy | ±0.1 mg/L | |
Calibration Reminder | Yes | |
Calibration Points | Air-saturated water or zero point | |
Barometric Compensation | Yes | |
Manual Salinity Factor Correction | Yes | |
% Saturation -Polarographic | Range | (0.0 to 600)% |
Resolution | 0.10% | |
Accuracy | ±2.0% | |
Temperature | Range | -5 to 130 ºC |
Unit | ºC | |
Resolution | 0.1℃ | |
Accuracy | ±0.1℃ | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Log Management | Yes | |
Inputs | pH Electrode | BNC(Q9) |
DO with Temp. Probe | 6-pin Mini-DIN | |
Conductivity with Temp. Probe | 8-pin Mini-DIN | |
Outputs | USB, RS 232 | USB 2.0 flash memory device, printer, PC |
Display options | Backlight | Yes |
Auto Shutdown | 1~60 min, off | |
IP Rating | IP54 | |
Date and Time | Yes | |
General | Power | AC Adapter, 100-240V AC input, DC24V output |
Dimensions | 280×280×130 mm | |
Weight | 2500g (5.51 lb) | |
Dimensions (Carton) | 370×305×330 mm | |
Weight (Gross) | 4 kg |