Anaerobic Incubator
What is Anaerobic Incubator?
The anaerobic incubator is a special device that can culture and operate bacteria in an anaerobic environment. It can provide strict anaerobic conditions and constant temperature culture conditions and has a systematic and scientific working area, which can cultivate very difficult-to-grow anaerobic organisms and can also avoid the risk of death of anaerobic organisms exposed to oxygen when operating in the atmosphere. Therefore, this device is ideal equipment for anaerobic biological monitoring and scientific research. This type of product generally consists of a constant temperature incubation room, an anaerobic operation room, a sampling room, a gas circuit and a circuit control system, a box rack, a bottle rack, a wax melting sterilizer, and other parts.
Features of Anaerobic Incubator
- Equipped with large LCD screen display or colorful touch screen,easy to operate;
- High-precision microcomputer control (with timing function) accurately and visually reflects the actual temperature inside the incubator, over heating alarm adopted, safe and reliable;
- UV Sterilizer effectively prevents bacterial contamination ;
- Switch control for solenoid valve, it can accurately adjust the flow and input any necessary gas;
- Stainless steel cultivation and operation room
- Transparent impact-resistant glass front window for easy observation;
- Latex gloves are comfortable and reliable, easy to us;
- Operation room is equipped with deoxidization catalyst.
- Designed with a double widen door, which can put more petri dishes.
- Imported oxygen sensors can observe oxygen concentration in the operating room at any time.
- Equipped with leakage protection.
- The operating room is equipped with special inoculating rod sterilizer and wax melting disinfection device.
Anaerobic Incubator LAI-3T
• Anaerobic state formation time: <1 hr
• Anaerobic maintenance time: >13 hrs
• LCD touch screen
Anaerobic Incubator LAI-3
• Anaerobic state formation time: <1 hr
• Anaerobic maintenance time: >13 hrs
• LCD display
Anaerobic Incubator LAI-3D
• Anaerobic state formation time: <1 hr
• Anaerobic maintenance time: >13 hrs
• LCD display
Anaerobic Incubator LAI-3DT
• Anaerobic state formation time: <1 hr
• Anaerobic maintenance time: >13 hrs
• LCD touch screen
Anaerobic Incubator LAI-3T-N
• Anaerobic state formation time: <70 minutes
• Anaerobic maintenance time: >13 hrs
• LCD touch screen
Anaerobic Workstation DW-LAI-D2
• Anaerobic state formation time: <1 hr
• Anaerobic maintenance time: >12 hrs
• LCD touch screen
Application of Anaerobic Incubator
Anaerobic incubator is a special device for culturing and operating bacteria in an oxygen-free environment. It is widely used in biomedical research, environmental protection engineering, microbial separation and drug development, scientific research and teaching, etc.
How to Choose Anaerobic Incubator?
- Airtightness: Good airtightness ensures that the inner cavity of the box is at a stable anaerobic level during operation and maintenance, which is the core requirement of the anaerobic incubator.
- Convenient operation: The design of the operation hole and the transfer cabin should be reasonable, which is convenient for the operator to enter and exit with both hands and transfer samples, while reducing the chance of outside air entering and maintaining the stability of the anaerobic state.
- Temperature and humidity control: The growth of anaerobic bacteria requires a suitable temperature and humidity environment, so temperature and humidity control is essential.
- Biological detoxification function: High-performance anaerobic incubators should have biological detoxification function to effectively remove metabolic waste gas in the inner cavity and ensure the good growth state of anaerobic bacteria.
- Disinfection and sterilization function: The disinfection and sterilization function of the inner cavity is also an important consideration. Anaerobic incubators that support ultraviolet disinfection and strong oxidizing disinfectants can better meet experimental needs.
- Real-time monitoring and alarm function: The equipment should have real-time monitoring and alarm functions to ensure the normal operation of the equipment and experimental safety.