Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES) is a widely used analytical technique for detecting and quantifying elements in a variety of samples. However, when analyzing complex matrices, interference challenges can impact accuracy and precision. Addressing these interferences is critical to obtaining reliable results. This article explores the types of interferences encountered in ICP-AES and practical strategies and innovative technologies to mitigate them.

ICP700T (1)

Types of Interference in ICP-AES

This chart provides a quick overview of the different interference types that can affect ICP-AES measurements and how they impact the accuracy of the analysis.

Type of InterferenceDescriptionExamplesHow It Affects Analysis
Spectral InterferenceOccurs when emission lines from different elements overlap, leading to false signals.Overlapping emission lines of two elementsResults in inaccurate readings for analytes due to confusion in signal detection.
Physical InterferenceCaused by physical properties of the sample matrix, such as viscosity, matrix loading, or aerosol formation.High matrix concentration, particle sizeAlters the sample introduction rate and plasma conditions, leading to signal suppression or enhancement.
Chemical InterferenceArises from chemical reactions that occur in the plasma or during sample preparation, affecting analyte ionization or emission.Formation of oxides, hydroxides, or carbonatesResults in reduced or enhanced signals due to inefficient ionization or excitation of analytes.
Ionization InterferenceOccurs when high concentrations of easily ionizable elements (EIEs) suppress the ionization of target analytes.Alkali and alkaline earth metals (e.g., Na, K, Ca)Suppresses or enhances analyte signals by disrupting ionization equilibrium.
Matrix InterferenceArises when the matrix components alter the emission signal of the analyte without being chemically reactive.High salt content, organic compoundsCauses signal enhancement or suppression due to the matrix’s impact on plasma characteristics.
Molecular InterferenceHappens when molecules in the sample form complex species that interfere with analyte emission.Polyatomic ions (e.g., CaOH, FeO)Interferes with the measurement of analytes due to the formation of molecular species that overlap analyte signals.
Instrumental InterferenceResults from issues within the ICP-AES system, such as detector saturation, drift, or instability.Detectors or nebulizer malfunctionLeads to erroneous results due to equipment errors or system instability.
ICP700T 3

Key Strategies to Address Interference in ICP-AES

1. Spectral Deconvolution

Resolves overlapping emission lines from different elements or matrix components.

Approaches:

  • Use high-resolution spectrometers to distinguish closely spaced emission lines.
  • Apply background correction algorithms to subtract interfering signals.

2. Internal Standardization

Compensates for signal fluctuations caused by matrix effects or instrument variability.

Implementation:

  • Add an internal standard with an emission line close to, but not interfering with, the target analyte.
  • Normalize analyte signals against the internal standard to improve quantification accuracy.

Examples of Internal Standards: Yttrium, scandium, or indium.

3. Matrix Matching

Mimics the sample matrix in calibration standards to minimize matrix effects.

Steps:

  • Adjust the chemical composition of calibration solutions to resemble the sample matrix.
  • Match acid concentration, ionic strength, and other relevant properties.

4. Ionization Buffers

Stabilize plasma conditions to counteract ionization interferences caused by high concentrations of easily ionizable elements (EIEs).

Example: Adding potassium or cesium as an ionization buffer can help maintain consistent plasma ionization.

5. Sample Preparation and Dilution

Reduces the concentration of interfering matrix components without compromising analyte detectability.

Techniques:

  • Dilute samples to reduce matrix load while maintaining sufficient analyte concentration.
  • Use digestion methods like microwave digestion to homogenize complex matrices.

6. Dynamic Range Optimization

Ensures measurements are within the linear dynamic range of the detector, avoiding distortions from overly intense signals.

Approaches:

  • Select alternative wavelengths with lower emission intensity for highly concentrated analytes.
  • Use multiple wavelengths to cross-check results.

7. Alternative Calibration Techniques

  • Standard Additions Method: Add known concentrations of the analyte to the sample matrix to account for matrix effects.
  • External Calibration with Matrix Matching: Use calibration standards closely resembling the sample’s matrix composition.
ICP-AES display

Key Innovations in ICP-AES for Mitigating Interferences

Advances in technology, instrumentation, and methodologies have significantly enhanced the ability of ICP-AES to overcome these interference challenges.

1. High-Resolution Spectrometers

Advances in spectrometer resolution have been one of the most significant developments in ICP-AES.

Impact on Interference

High-resolution spectrometers can resolve closely spaced emission lines from different elements, minimizing spectral overlap, which is one of the most common forms of interference.

How It Helps

With improved resolution, ICP-AES systems can distinguish between emission lines from analytes and those of matrix components or other elements, significantly reducing spectral interference. Additionally, they enable better background correction, allowing for more accurate measurements in complex samples.

2. Dual-View ICP-AES

Dual-view technology allows users to switch between radial and axial viewing modes in ICP-AES.

Impact on Interference

  • Radial Viewing: Provides lower sensitivity but reduces matrix effects and physical interferences from high concentrations of elements in the sample.
  • Axial Viewing: Offers higher sensitivity for trace element analysis but may be more susceptible to matrix interferences.

How It Helps

The ability to switch between these viewing modes based on the complexity of the sample allows for better control over physical and chemical interferences. Dual-view ICP-AES helps optimize signal acquisition by balancing sensitivity and minimizing matrix effects.

3. Multi-Element Detection and Wavelength Selection

Advances in multi-element detection capabilities and wavelength selection have helped overcome interference challenges in ICP-AES.

Impact on Interference

  • The use of multiple wavelengths for a single analyte can help identify and correct spectral interferences.
  • Modern ICP-AES systems can simultaneously detect several elements at various wavelengths, allowing for cross-checking and validation of results.

How It Helps

By utilizing different wavelengths, ICP-AES systems can more accurately detect analytes even in the presence of interferences, providing a more comprehensive and reliable analysis. This is especially useful when dealing with complex samples containing many overlapping signals.

4. Use of Reaction and Collision Cells

While primarily a feature in ICP-MS, reaction and collision cells have been adapted for ICP-AES in some advanced systems.

ICP-MS DW-SUPEC7000 Inductively Coupled Plasma Mass Spectrometer Manufacturers

Impact on Interference

These cells allow for the selective removal of molecular interferences, particularly from polyatomic ions, which are common in complex matrices.

How It Helps

By introducing reactive gases or using collision cells, ICP-AES can reduce the formation of interfering molecular species, such as hydroxides or oxides, thus increasing the precision of trace element analysis.

5. Improved Plasma Source and Power Control

Advances in plasma technology, including better plasma generators and improved RF power control, contribute to more stable and efficient plasma conditions.

Impact on Interference

  • Stable plasma reduces variations in excitation and ionization that can lead to matrix effects.
  • By optimizing the RF power and gas flow rates, modern ICP-AES systems can maintain a consistent plasma temperature, which is crucial for minimizing physical interferences, particularly those related to aerosol formation.

How It Helps

Improved plasma stability ensures that analyte ions are efficiently excited and detected, reducing the likelihood of matrix suppression or enhancement. It also leads to more reproducible results, especially when analyzing samples with varying matrix compositions.

6. Software Advancements and Spectral Interference Correction

Advanced software algorithms have been developed to automatically detect and correct for spectral interferences.

Impact on Interference

Software now plays a significant role in addressing both spectral and matrix interferences by using advanced algorithms to deconvolve overlapping signals, adjust for background noise, and perform real-time corrections during analysis.

How It Helps

These software tools significantly enhance the accuracy and efficiency of ICP-AES by automatically identifying interferences and applying the necessary corrections. This reduces the need for manual intervention and improves the reliability of data, particularly when dealing with complex sample matrices.

Advanced software in ICP-AES

7. Laser Ablation ICP-AES (LA-ICP-AES)

Laser Ablation (LA) combined with ICP-AES allows for the direct analysis of solid samples, such as metals, ceramics, and geological materials, without extensive sample preparation.

Impact on Interference

  • LA-ICP-AES can help minimize matrix effects by enabling direct sample analysis, often avoiding the complex digestion steps that can introduce interferences.
  • Laser ablation offers precise spatial resolution, reducing the influence of matrix variability across the sample.

How It Helps

LA-ICP-AES offers an alternative to traditional liquid sample analysis, especially when dealing with heterogeneous or challenging solid samples. The ability to perform rapid, localized analysis helps minimize sample preparation errors and matrix interference.

8. On-Line and Real-Time Monitoring Systems

Advanced on-line and real-time monitoring capabilities have been integrated into ICP-AES systems to assess and adjust parameters such as sample introduction, nebulizer efficiency, and plasma conditions during analysis.

Impact on Interference

These systems ensure that any fluctuations in sample delivery or plasma stability can be quickly identified and corrected during the analysis, reducing potential interference from inconsistent sample introduction or plasma instability.

How It Helps

By continuously monitoring the system’s performance, these innovations allow for real-time adjustments, reducing the likelihood of interference and improving the robustness of ICP-AES in complex sample environments.

In summary, through implementing a combination of advanced techniques such as spectral deconvolution, matrix matching, modern instrumentation, optimized calibration methods ,etc, ICP-AES users can mitigate interference challenges, particularly when working with complex matrices. Adopting innovative technologies in high-resolution spectrometry, dual-view systems, reaction cells, improved plasma control,etc, ICP-AES can now deliver more accurate, reliable, and precise results even in the presence of various types of interference.

Related Products Recommendation