Infrared (IR) spectroscopy is a powerful technique used to probe the vibrational modes of molecules. This provides a unique “fingerprint” of a substance, allowing for identification, structural analysis, and even quantitative measurements. Within the realm of IR spectroscopy, three main methods stand out: Fourier Transform Infrared (FTIR), traditional Infrared (often referred to as Mid-IR), and Near-Infrared (NIR) spectroscopy. While all three leverage the interaction of infrared light with matter, they differ significantly in their instrumentation, applications, and the type of information they provide. This article will delve into the nuances of each technique, offering a comprehensive guide to help you choose the best method for your specific needs.

What is IR Spectroscopy?
Infrared spectroscopy exploits the fact that molecules vibrate at specific frequencies when exposed to infrared light. These vibrations, corresponding to stretching, bending, and other molecular motions, are unique to each molecule. When infrared light interacts with a sample, certain wavelengths are absorbed, while others are transmitted. By analyzing the pattern of absorbed and transmitted light, we can generate an infrared spectrum, which is a plot of absorbance or transmittance versus wavenumber (related to frequency). This spectrum acts as a fingerprint of the molecule, providing valuable information about its structure and composition.
Within the IR region, we can broadly distinguish three sub-regions: Near-Infrared (NIR), Mid-Infrared (Mid-IR), and Far-Infrared. Here we focuses primarily on NIR and Mid-IR, as they are the most commonly used.

Overview of FTIR, IR, and NIR:
FTIR(Fourier transform infrared spectroscopy): FTIR utilizes an interferometer to generate a complex signal containing all infrared frequencies simultaneously. This signal is then mathematically transformed using Fourier analysis to produce the spectrum. FTIR covering the mid-infrared region (4000-400 cm⁻¹), offering high resolution, sensitivity, and speed, making it suitable for complex sample analysis.
Mid-IR ((Traditional infrared spectroscopy)): Traditional IR spectroscopy typically employs a dispersive instrument that separates infrared light into its constituent wavelengths. These wavelengths are then sequentially passed through the sample. While simpler and often less expensive than FTIR, Mid-IR generally exhibits lower resolution and slower data acquisition, and is now mostly replaced by FTIR.
NIR(Near infrared spectroscopy): NIR spectroscopy focuses on the near-infrared region(12500-4000 cm⁻¹), which contains overtones and combination bands of fundamental vibrations. NIR offers the advantage of deeper sample penetration and is often suitable for non-destructive analysis. It is particularly useful for analyzing complex matrices and for quantitative measurements.
The core of infrared spectroscopy is “molecular fingerprint” recognition, but different technologies have different applicable scenarios due to differences in spectral range and detection principles. Understanding its basic principles is the prerequisite for choosing a reasonable method.

Key Differences Between FTIR, IR, and NIR
When comparing FTIR, IR, and NIR, it’s essential to consider their fundamental differences to determine which technique best suits your requirements.
Spectral Range and Information Depth
FTIR/IR: Focusing on the mid-infrared region, directly detecting fundamental frequency vibration, and providing clear functional group information (such as the characteristic peak of carbonyl C=O at 1700 cm⁻¹).
NIR: The signal comes from the double frequency and combined frequency of weak absorption, and the spectrum overlaps seriously, requiring chemometric model analysis (such as PLS regression).
Comparison of Technical Performance
Parameter | FTIR | NIR | Traditional IR |
Resolution | High (up to 0.5 cm⁻¹) | Low (model-dependent) | Medium (1-4 cm⁻¹) |
Scan Speed | Fast (full spectrum in seconds) | Extremely fast (milliseconds) | Slow (minutes) |
Sample Requirement | Requires preparation (e.g., KBr pellet) | Can directly measure original sample | Requires preparation |

Differences in Application Scenarios
- FTIR: Analysis of drug crystal forms, identification of microplastics, study of mineral phase transitions.
- NIR: Detection of moisture in grains, monitoring uniformity of tablet coatings, online control in the petroleum industry.
- Traditional IR: Teaching demonstrations, basic functional group identification (e.g., distinguishing between alcohols and ketones).
FTIR excels in in-depth analysis, NIR is advantageous for rapid, non-destructive measurements, while traditional IR is gradually fading from mainstream use. The choice depends on the trade-off between information depth and efficiency requirements.

How to Choose the Best Method for Your Needs
Selecting the best IR spectroscopy method requires careful consideration of several factors, including the nature of the sample, the desired information, the cost and availability of instrumentation, and the required sensitivity and resolution.
Analysis Target
- Qualitative Analysis (e.g., Unknown Substance Identification): Choose FTIR due to its high resolution, which can distinguish subtle structural differences (such as cis and trans isomers).
- Quantitative Analysis (e.g., Moisture Content): Prioritize NIR, combined with PLS models for rapid prediction.
Sample Type and State
- Solid/Thin Film: FTIR with an ATR (Attenuated Total Reflectance) accessory can directly analyze the sample.
- Liquid/Gas: FTIR with a gas cell or liquid cell is more sensitive (e.g., detecting ppm levels of CO₂ in the atmosphere).
- Living or Large-Volume Samples: NIR fiber optic probes can perform non-contact measurements (e.g., online sorting of fruit based on sugar content).
Environmental and Cost Constraints
- Laboratory Setting: FTIR is suitable for precise research.
- Industrial Site: Portable NIR supports real-time quality control.
- Limited Budget: Traditional IR instruments are lower in price but have limited functionality.
Sensitivity and Resolution
If high sensitivity and resolution are critical for detecting minor components or distinguishing closely spaced peaks, FTIR is usually the preferred method. For applications where sensitivity is less critical, Mid-IR or NIR might be sufficient.
Decision-Making Process:
- Define your analytical objective: What information are you trying to obtain from your sample?
- Characterize your sample: What is its physical state, composition, and homogeneity?
- Consider the desired information: Do you need qualitative or quantitative data? What level of detail is required?
- Evaluate cost and availability: What is your budget? What instruments are readily available?
- Assess sensitivity and resolution requirements: How sensitive does the measurement need to be? How well-resolved do the spectral features need to be?
By carefully considering these factors, you can make an informed decision and choose the IR spectroscopy method that best suits your needs.