EP/EPP Adjustable Autoclavable Pipette

EP/EPP adjustable autoclavable pipette is widely used in clinical diagnostic laboratories, biotechnology laboratories, pharmacy and chemistry laboratories, environmental laboratories, food laboratories, electromechanical laboratories, etc.

EP and EPP Adjustable Autoclavable Pipette

Features of EP Adjustable Autoclavable Pipette

  • Professional design. Unique shape. Comfortable handle.
  • In accordance with Human engineering.
  • Special metal materials to ensure the durability, accuracy and stability, and to guarantee no maintenance in one year.
  • All-around lock catch to let operator lock range, making adjustable pipette be used as fixed pipettes with various range.
  • Operators can calibrate pipette independently by tool in each package.
Model No.Volume (µL)Increment (µL)Rel. %Abs (µL)Rel. CV%Abs SD (µL)
EP20.20.00212.00.0246.000.012
 1 2.70.0271.300.013
 2 1.50.0300.700.014
EP1010.022.50.0251.200.012
 5 1.50.0750.600.030
 10 1.00.1000.400.040
EP2020.027.50.152.000.040
 10 1.50.150.500.050
 20 1.00.200.300.060
EP5050.027.50.152.000.040
 25 1.50.150.500.050
 50 1.00.200.300.060
EP100100.23.50.351.000.10
 50 0.80.400.240.120
 100 0.80.800.150.150
EP200200.22.50.51.000.200
 100 0.80.80.250.250
 200 0.81.600.150.300
EP300300.22.50.51.000.02
 150 0.80.80.250.25
 300 0.81.600.150.30
EP1000 1002.03.03.00.600.600
 500 0.84.00.201.000
 1000 0.88.00.151.5
EP50005005.02.412.00.603.0
 2500 0.615.00.205.0
 5000 0.618.00.168.0

Features of EPP Adjustable Autoclavable Pipette

  1. Fully autoclavable. ( 121℃ for 20 minutes )
  2. Enhanced UV resistance.
  3. Easy digital volume setting.
  4. Easy and convenient single hand locking lever.
  5. Eight sizes to cover a wide volume range. ( 0.1μL – 10mL )
  6. PTFE ( Fluorine resin ) is used in the airtight chamber of the instrument, so the instrument keeps its air tightness and precise reproducibility for long hours.
  7. Filtered Nozzles are used for volume models larger than 1000μL.
  8. Tip ejector allows tip ejections without touching the tip.
  9. Tip ejector is made of plastic to avoid damaging glass tubes.
Model No.Volume (L)Increment (L)Rel.%-% Abs LRel.CV%・CV%Abs SD L
EPP20.20.00212.00.0246.000.012
 1 2.70.0271.300.013
 2 1.50.0300.700.014
EPP1010.022.50.0251.200.012
 5 1.50.0750.600.030
 10 1.00.1000.400.040
EPP2020.027.50.152.000.040
 10 1.50.150.500.050
 20 1.00.200.300.060
EPP5050.027.50.152.000.040
 25 1.50.150.500.050
 50 1.00.200.300.060
EPP100100.23.50.351.000.10
 50 0.80.400.240.120
 100 0.80.800.150.150
EPP200200.22.50.51.000.200
 100 0.80.80.250.250
 200 0.81.600.150.300
EPP300300.22.50.51.000.02
 150 0.80.80.250.25
 300 0.81.600.150.30
EPP0001002.03.03.00.600.600
 500 0.84.00.201.000
 1000 0.88.00.151.5
EPP50005002.02.412.00.603.0
 2500 0.615.00.205.0
 5000 0.618.00.168.0
EPP1000010002.03.03.00.600.6
 5000 0.84.00.201.0
 10000 0.88.00.151.5