DW-TS100 Thermo Shaker
DW-TS100 thermo shaker is a temperature controlled shaker, which is useful for a variety of molecular biology applications. Speed, time and temperature settings are continuously visible on the LCD, simultaneously showing both actual and selected values. Integral over-temperature control ensures long time, safety and sample integrity.
Features of DW-TS100 Thermo Shaker
- LCD display. It is easy to setup and use.
- Reliable design with inner extra temperature protection.
- Each device is equipped with lifter that is easy to replace different blocks.
- Digital accuracy and convenience.
- Precision wells for uniform thermal transfer.
- Assorted blocks for a wide variety of tube sizes.
- Brushless DC Motor: noiseless long service life maintenance-free.
- Conform to CE safety standard.
- Accurately control and display time, temperature and speed.
Applications of DW-TS100 Thermo Shaker
- Storing enzymes or DNA libraries at your work station.
- Transporting samples from the field at exactly the right temperature.
- Heating samples in the field.
- Enzyme reactions and deactivations.
- PCR sample preparation.
Parameters of DW-TS100 Thermo Shaker
Model | DW-TS100 |
Temp setting range | 0℃~100℃ |
Temp control range | RT.+5℃~100℃ |
Time range | 1min ~ 99h59min/∞ |
Temp accuracy | ≤±0.3℃* |
Display accuracy | 0.1℃ |
Temp uniformity | ≤±0.3℃* |
Speed range | 200~1800rpm |
Orbit | 3mm |
Heating time | ≤12min(from 25℃ to 100℃)* |
Multi point running | Yes(Max 5points) |
Multi cycle | Yes(Max 99times) |
Auto heating | Yes |
Auto running | Yes |
Auto resume to run | Yes |
Power supply | 150W |
Voltage | AC220V or AC110V/50-60Hz |
Fuse | 250V 3A Ф5×20 |
Dimension(mm) | 260x195x150 |
Weight(kg) | 7.0 |
Optional Blocks
Type | Capacity | Temp range | Max Speed |
MD30 | 96×0.2ml | 0℃~100℃ | 1800rpm |
MD31 | 54×0.5ml | 0℃~100℃ | 1800rpm |
MD32 | 35×1.5ml | 0℃~100℃ | 1800rpm |
MD33 | 35×2.0ml | 0℃~100℃ | 1800rpm |
MD34 | 20×1.5ml+15×0.5ml | 0℃~100℃ | 1800rpm |
MD35 | 96×0.2ml | 0℃~100℃ | 1800rpm |
MD36 | 24x5ml | 0℃~100℃ | 1000rpm |
MD37 | 15x10ml | 0℃~100℃ | 1000rpm |
MD38 | 12x15ml | 0℃~100℃ | 800rpm |
MD39 | 6x50ml(round-shape bottom) | 0℃~100℃ | 800rpm |
MD39-S | 6x50ml(cone-shape bottom) | 0℃~100℃ | 800rpm |