DW-ES1000 Dry Bath Incubator (Heating lid)

The DW-ES1000 Dry Bath Incubator is a semi-conductor controlled heating & cooling instrument with automatic temperature control design. The flexible timer, constant temperature function and multi-point operation mode make it a unique and an ideal lab instrument.

Features of DW-ES1000 Dry Bath Incubator

  1. Instantly displays operation information on the LCD screen.
  2. Has combined temperature control system and block system. Each block has a built-in temperature sensor and heating/cooling unit, ensuring that temperature control is more accurate and the heating speed is much faster.
  3. Interchangeable, auto-recognized blocks.
  4. Adjustable heating lid. Temperature of heating lid can be controlled.
  5. Multi-point(max. 5 points) and Multi-cycle( Max.99 times) operation modes are provided.
  6. Auto restart in case of power failure.
  7. Over-heating protection device is included.
  8. Built-in temperature calibration function.

Parameters of DW-ES1000 Dry Bath Incubator

ModelDW-ES1000
BlockDW-ES seriesDW-ESC series
Temp setting range0℃~100℃-10℃~100℃
Temp control rangeRT+5℃~100℃RT.-25℃~100℃
Time range1sec ~ 99h59min/∞1sec ~ 99h59min/∞
Temp accuracy≤±0.3℃@37℃≤±0.3℃@37℃
Display accuracy0.1℃0.1℃
Temp uniformity≤±0.3℃@37℃≤±0.3℃@37℃
Heating time≤12min(from 25℃ to 100℃)*≤12min(from 25℃ to 100℃)*
Cooling time 1≤12min(from 100℃ to 25℃)*
Cooling time 2≤25min(from RT to RT-25℃)*
Heating lid temp setting rangeOFF~+10℃OFF~+10℃
Heating lid temp accuracy≤±0.5℃*≤±0.5℃*
Heating lid heating time≤10min(from 25℃ to 100℃)*≤10min(from 25℃ to 100℃)*
Storage at 4℃Yes *
Multi-points runningYes(Max 5points)Yes(Max 5points)
Multi-cycleYes(Max 99times)Yes(Max 99times)
Auto runningYesYes
Auto heatingYesYes
Auto resume to runYesYes
CapacitySee optional block See optional block
Power150W150W
VoltageAC110 or AC220V/50-60HZAC110 or AC220V/50-60HZ
Fuse250V  3A  Ф5×20250V  3A  Ф5×20
Dimension(mm)300x200x210 300x200x210
Weight(kg)4.04.7

* Test condition:RT.25℃±2℃, block is 1.5mlx35, use mercurial thermometer, accuracy is ±0.1℃.

Optional Blocks

TypeCapacityTemp. range
ESC-0135×2.0ml centrifuge tubeRT-25℃~100℃
ESC-0235×1.5ml centrifuge tubeRT-25℃~100℃
ESC-0354×0.5ml centrifuge tubeRT-25℃~100℃
ESC-0496×0.2ml centrifuge tubeRT-25℃~100℃
ESC-0596×0.2ml Elisa plateRT-25℃~100℃
ES-0635×2.0ml centrifuge tubeRT+5℃~100℃
ES-0735×1.5ml centrifuge tubeRT+5℃~100℃
ES-0854×0.5ml centrifuge tubeRT+5℃~100℃
ES-0996×0.2ml centrifuge tubeRT+5℃~100℃
ES-1096×0.2ml Elisa plateRT+5℃~100℃
ES-series-blocks