DW-E Series Universal Power Supply
DW-E series universal power supply include 10 models, the maximum output voltage varies from 200V to 10000V, can widely cover most electrophoresis experiments, DRAWELL can provide different types of power supplies for experiments with different uses.
DW-E series universal power supply is based on the DW-C series universal power supply on the optimization of control program, expansion the product function, which simplifies the operation, and greatly improve the performance of the electrophoresis power supply.
Features of DW-E Series Universal Power Supply
- Molding shell, touch keys, dual-core microprocessor, intelligent control.
- 0-9 digital button, easy and convenient to operate.
- Indicate the preset value and the actual output value at the same time.
- Can store 100 electrophoresis methods.
- Automatic memory function.
- Step-by-step control function (editable 10 groups, each group of up to 10 program automatic connection operations).
- Pause control function (including real-time tuning)
- Standard, timing, V-hr, step-by-step operation function.
- Constant voltage, constant current, constant power, misoperation, fault and other warning functions.
- Automatic detection of no-load, overload, short circuit, rapid resistance change, ground leak, and system overheating.
Parameters of DW-E Series Universal Power Supply
Model | DW300E | DW600E | DW1000E |
Voltage range | 5~300 V | 10~600 V | 30~1000 V |
Current range | 1~400 mA | 1~500 mA | 1~500 mA |
Power range | 1~120 W | 1~300 W | 1~300 W |
Type of control | Constant V,Constant l and Constant P | Constant V,Constant l and Constant P | Constant V,Constant l and Constant P |
Display type | LCD screen with backlight | LCD screen with backlight | LCD screen with backlight |
Output jack | Four sets | Four sets | Four sets |
Storage function | Store 100 methods | Store 100 methods | Store 100 methods |
Programming method | Can store 10 methods each up to 10 steps | Can store 10 methods each up to 10 steps | Can store 10 methods each up to 10 steps |
Timing function | 1min-99h59min | 1min-99h59min | 1min-99h59min |
V-hr function | Yes,1~99999 V-hr | Yes,1~99999 V-hr | Yes,1~99999 V-hr |
Pause control function | Yes | Yes | Yes |
Power recovery function | Optional | Optional | Optional |
Automatic memory function | Yes | Yes | Yes |
Automatic shutdown function | Yes | Yes | Yes |
Intelligent prompt functions | Yes | Yes | Yes |
Non-proliferation field function | Optional | Optional | Optional |
Temperature detection function | No | No | No |
Safety performance | Yes | Yes | Yes |
Molding machine casing | Yes | Yes | No |
Dimension (LxWxH) | 280×237×118(mm) | 280×237×118(mm) | 263×275×125(mm) |
Weight | 3.2 kg | 3.2 kg | 4.6kg |
Model | DW-600HE | DW-300HE | DW-200E |
Voltage range | 5~600 V | 0~300V | 5~200 V |
Current range | 1~1000 mA | ~1500mA | ~2000 mA |
Power range | ~300 W | ~450 W | ~200 W |
Type of control | Constant V, Constant I | Constant V, Constant l | Constant V, Constant and Constant P |
Display type | LCD screen with backlight | CD screen with backlight | LCD screen with backlight |
Output jack | Four sets | Four sets | Four sets |
Storage function | Store 100 methods | Store 100 methods | Store 100 methods |
Programming method | Can store 10 methods each up to 10 steps | Can store 10 methods each up to 10 steps | Can store 10 methods each up to 10 steps |
Timing function | min-99h59min | 1min-99h59min | 1min-99h59min |
V-hr function | Yes,1~99999 V-hr | Yes,1~99999 V-hr | Yes,1~99999 V-hr |
Pause control function | Yes | Yes | Yes |
Power recovery function | Optional | Optional | Optional |
Automatic memory function | Yes | Yes | Yes |
Automatic shutdown function | Yes | Yes | Yes |
Intelligent prompt functions | Yes | Yes | Yes |
Non-proliferation field function | Optional | Optional | Optional |
Temperature detection function | No | No | No |
Safety performance | Yes | Yes | Yes |
Molding machine casing | No | Yes | Yes |
Dimension (LxWxH) | 263×275×125(mm) | 280×237×118(mm) | 280×237×118(mm) |
Weight | 4.4 kg | 3.2 kg | 3.2 kg |
Model | DW-1600E | DW-3000E | DW-5000E | DW-10000E |
Voltage range | 10~1600V | 20~3000V | 20~5000V | 20~10000 V |
Current range | 1~200mA | 1~400 mA | ~200 mA | ~3500μA |
Power range | 1~320W | 1~400 W | 1~100 W | 1~35 W |
Type of control | Constant V,Constant and Constant P | and Constant P | Constant V,Constant l | Constant V,Constant l and Constant P |
Display type | CD screen with backlight | LCD screen with backlight | CD screen with backlight | CD screen with backlight |
Output jack | Four sets | Four sets | Two sets | Two sets |
Storage function | Store 100 methods | Store 100 methods | Store 100 methods | store 100 methods |
Programming method | Can store 10 methods each up to 10 steps | Can store 10 methods each up to 10 steps | Can store 10 methods each up to 10 steps | each up to 10 steps |
Timing function | 1min-99h59min | 1min-99h59min | 1min-99h59min | 1min-99h59min |
V-hr function | Yes,1~99999 V-hr | Yes,1~99999 V-h | Yes,1~99999 V-hr | Yes,1~99999 V-br |
Pause control function | Yes | Yes | Yes | Yes |
Power recovery function | Optional | Optional | Optional | Optional |
Automatic memory function | Yes | Yes | Yes | Yes |
Automatic shutdown function | Yes | Yes | Yes | Yes |
Intelligent prompt functions | Yes | Yes | Yes | Yes |
Non-proliferation field function | Optional | Optional | Optional | Optional |
Temperature detection function | No | No | Yes | Yes |
Safety performance | Yes | Yes | Yes | Yes |
Molding machine casing | No | No | No | No |
Dimension (LxWxH) | 263×275×125(mm) | 263×275×125(mm) | 368×255×133(mm) | 370×255×133 (mm) |
Weight | 4.4 kg | 4.8 kg | 10.6kg | 12.0 kg |