DW-C Series Universal Power Supply
DW-C series universal power supply including 9 models, the maximum output voltage varies from 200V to 3000V, can widely cover most electrophoresis experiments, DRAWELL can provide different types of power supplies for experiments with different uses.
- Type of Output: Constant voltage, constant current or constant power
- Increment: 1V,1mA,1W
- Timing Range:1min~99hr,59min
- Display: LCD display with backlight
Features of DW-C Series Universal Power Supply
- Molding shell, touch keys, dual-core microprocessor, intelligent control.
- Indicate the preset value and the actual output value at the same time.
- Can store 10 electrophoresis methods.
- Automatic memory function.
- Standard timing operation function.
- Constant voltage, constant current, constant power, mis-operation, fault and other warning functions.
- Automatic detection of no-load, overload, short circuit, rapid resistance change ,ground leak and system overheating.
Parameters of DW-C Series Universal Power Supply
Model | DW-200C | DW300C | DW600C |
Voltage range | 5~200V | 5~300V | 10~600 V |
Current range | 1~2000 mA | 1~400 mA | 1~500 mA |
Power range | ~200 W | 1~120W | 1~300 W |
Type of control | Constant V, Constant I and Constant P | Constant V, Constant I and Constant P | Constant V, Constant I and Constant P |
Display type | CD screen with backlight | LCD screen with backlight | LCD screen with backlight |
Output jack | Four sets | Four sets | Four sets |
Storage function | Store 10 methods | Store 10 methods | Store 10 methods |
Programming method | No | No | No |
Timing function | min-99h59min | min-99h59min | min-99h59min |
V-hr function | No | No | No |
Pause control function | Yes | Yes | Yes |
Power recovery function | Optiona | Optional | Optional |
Automatic memory function | Yes | Yes | Yes |
Automatic shutdown function | Yes | Yes | Yes |
Intelligent prompt functions | Yes | Yes | Yes |
Non-proliferation field function | Optional | Optional | Optional |
Temperature detection function | No | No | No |
Safety performance | Yes | Yes | Yes |
Molding machine casing | Yes | Yes | Yes |
Dimension (LxWxH) | 280x237x118(mm) | 280x237x118(mm) | 280×237×118(mm) |
Weight | 3.2kg | 3.2 kg | 3.2kg |
Model | DW-300HC | DW-600HC | DW-ECPT3000 |
Voltage range | 10~300 V | 10~600 V | 20~3000 V |
Current range | 1~1500 mA | 1~1000 mA | 1~200 mA |
Power range | ~450 W | ~300 W | ~200 W |
Type of control | Constant V,Constant and Constant P | Constant V,Constant I and Constant P | Constant V,Constant I and Constant P |
Display type | CD screen with backlight | _CD screen with backligh | LCD screen with backlight |
Output jack | Four sets | Four sets | Four sets |
Storage function | 5tore 10 methods | 5tore 10 methods | Store 10 methods |
Programming method | No | No | No |
Timing function | min-99h59min | min-99h59min | min-99h59min |
V-hr function | No | No | No |
Pause control function | Yes | Yes | Yes |
Power recovery function | Optional | Optional | Optional |
Automatic memory function | Yes | Yes | Yes |
Automatic shutdown function | Yes | Yes | Yes |
Intelligent prompt functions | Yes | Yes | Yes |
Non-proliferation field function | Optional | Optional | Optional |
Temperature detection function | No | No | Yes |
Safety performance | Yes | Yes | Yes |
Molding machine casing | Yes | No | No |
Dimension (LxWxH) | 280×237×118(mm | 263×275×125(mm) | 263×275×125(mm) |
Weight | 3.2 kg | 4.4 kg | 7.0kg |