DW-8000 Handheld XRF Gold Analyzer
The DW series analyzers are configured with powerful miniature X-ray tubes, Si-PIN detectors or highly advanced silicon drift detectors (SDDs), specialized filters, and multibeam optimization for the ultimate in XRF field analysis. The actual overall value of the DRAWELL analyzer is embodied in the following: it can make correct decisions in real-time without relying on laboratory tests far away from the detection environment.
Features of DW-8000 Handheld XRF Gold Analyzer
- One-key power-on/off operation and automatic calibration without manual operation;
- 45s from startup to testing, and 0.8s reading of the grade and other data;
- One-key sample testing, with software for automatic timing lock and stop;
- Automatic X-ray shutdown within 2s in the absence of samples in front of the test window.
Applications of DW-8000 Handheld XRF Gold Analyzer
Specifications of DW-8000 Handheld XRF Gold Analyzer
Weight | Device: 1.50kg, 1.65kg with battery. |
Dimension | 250mm x 75mm x 270mm (L*W*H) |
Excitation source | High-power high-performance X-ray microtube |
Target materials | Five target materials of X-ray tube available:gold (Au), silver (Ag), tungsten (W), tantalum (Ta) and palladium (Pd) |
Voltage | 35kV-50kV voltage (changeable) |
Filter | A variety of selectable filters, automatically adjusted according to different tested objects |
Detector | High-resolution Si-Pin detector |
Detector refrigeration temperature | Peltier effect semiconductor refrigeration system |
Standard film | External 316 standard film/window protection cover (Optional built-in standard film, plus version) |
Power supply | 1 lithium battery (7.2v\6600mAh) |
Processor | High-performance ARM pulse processor |
Data processing | 32G large-capacity data storage card: ≥80,000 sets of data and spectrograms; |
Display screen | High-resolution TFT industrial-grade colored high-definition touch screen, it is ergonomic, sturdy, dust-proof, and waterproof, clearly visible under any light conditions |
Outline design | The integrated designed body is sturdy, waterproof, dustproof,antifreeze, shockproof, and can be used normally in harsh environments. |
Safe operation | “One key” detection, auto-lock, detection auto-stop functions. The X-ray will automatically be turned off if there is no sample in front of the detection window for 2 seconds. 3/2 of the shell of the device is covered with a 6061 aluminum alloy frame design, with better X-ray blockage. |
Detection Report | Customized detection report available as per the customers’ demands |
Element analysis | Au, Pt, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Hf, Ta, W, Pb, Bi, Zr, Nb, Mo, Cd, Sn, Sb, Re, In, Ag,Pd, Ru, Rh, Ir, etc. |