DTR3000 Portable Raman Spectrometer
A Portable Raman spectrometer is suitable for field operation. The outstanding reliability makes the detection result much more accurate. The excellent low stray light conditions that enable the spectrometer has a wide range of application, especially in public safety, food safety, and pharmaceutical engineering. The multi-function software facilitated the spectral analysis process in application and the remote experiment through
Internet access makes the test item much easier.
Features of DTR3000 Portable Raman Spectrometer
- Ultra-high sensitivity FFT-CCD TE-cooled;
- low noise circuit;
- Powerful embedded software;
- Fluorescent background eliminate;
- Peak finding and display;
- 10.1-Inch LCD;
- Win 10 operation system;
- 11.6-inch capacitive touch screen, multi-touch;
- USB 2.0;
- User friendly human-machine interface;
- Battery life> 3h;
- Remote control via LAN;
- IP67 case;
Application of DTR3000 Portable Raman Spectrometer
- Biological science
- Pharmaceutical engineering
- Forensic analysis
- Agriculture and food safety
- Gemstone
- Environmental science
Specifications of DTR3000 Portable Raman Spectrometer
DTR3000 System |
|||
Interface |
USB 2.0 and WIFI |
||
Operating system |
Android |
||
Screen |
11.6-inch capacitive touch screen, Multi-touch |
||
Battery life |
>4 h |
||
Integration time |
4ms – 120s |
||
Power voltage |
DC 19V(+/-5%) |
||
Operating Temp |
-10~40 ℃
|
||
Operating humidity |
< 95% |
||
Dimension(L*W*H) |
40X30X18 cm3 |
||
Weight |
7.5 Kg |
||
Reliability |
|||
Spectral stability |
σ/μ < 0.5% (COT 8 hours) |
||
Temp stability |
Spectral shift ≤ 1 cm-1 (10-40℃) |
||
Variation of intensity (in 5 ~ 40 °C) |
<±5% |
||
Optical parameters |
|||
Spectral range (cm-1) |
150-2600 |
200-3500 |
200-4300 |
resolution (cm-1) |
5 |
5 |
6 |
SNR |
>3000:1 (918 cm-1 of Acetonitrile,10s accumulation, 200mW) |
||
Entrance slit |
50 μm |
||
Optical system |
f/4 C-T crossed optical path |
||
focusing |
98 mm for incidence and output |
||
Detector |
|||
Item |
Ultra-high sensitivity, quick cooling CCD |
||
Detector cooled down to |
-10℃ |
||
Detecting range |
200-1100 nm |
||
Effective pixels |
2048*64 |
||
Dynamic range |
50000: 1 |
||
Pixel size |
14 μm x14 μm |
||
Full well capacity |
300 Ke- |
||
Sensitivity |
QE>40%, 6.5 μ V/e- |
||
Exciting Laser |
Central wavelength |
785nm (+/-1nm) |
FWHM |
0.08 nm |
Power output |
≥500 mW |
Power stability |
σ/μ <±0.20% |
Raman probe |
|
Operating distance |
6 mm |
Rayleigh scattering resistance |
OD>8 |
Numerical Aperture |
0.3 |
Aperture |
7mm |