DL-4M CGF Variable Speed Centrifuge

What is CGF?

CGF (Concentrated Growth Factor) is extracted from autologous blood by our specialized variable speed centrifuge DL4-M. The concentration of growth factor is four times higher than that of normal blood active substances and it contains CD34 positive cells and white blood cells with high activity. CD34 positive cells are important Cells for promoting the reconstruction of the micro-circulatory system and collagen regeneration. In the mesoderm, filling and wound repair, micro-capillary and micro-lymphatic systems can be quickly reconstructed in the treatment.

Features of DL-4M CGF

  1. 3 different running speeds/ RCF, 6 Kinds of Automatic Switching of Acceleration and Deceleration.
  2. Self-ventilated rotor system, compressor temperature control, and keep low temperature (15℃) working environment.
  3. Customize made for UV sterilize Light
  4. All parts of the rotor can be High Temperature and High-Pressure Sterilization.
  5. Can make PRP PRF CGF blood active substance.
  6. A swing Rotor is more effective for CGF extraction.
DL-4M CGF Variable Speed Centrifuge
DL-4M CGF Variable Speed Centrifuge
parts of DL-4M CGF Variable Speed Centrifuge

Technical parameters of DL-4M CGF

Model

DL-4M

NO.1 Swing Rotor

8*10ml

4000r/min

3250xg

Program

No.1

No.2

No.3

No.4

PRP

PRF

CGF

adjustable

Motor

Microprocessor &Brushless DC Motor

Temperature Range

-20℃~+40℃

Timer Range

0~99min

Noise

≤50dB(A)

Power Supply

AC220V&110V50Hz 2A

Dimension

540*340*312mm(L*W*H)

Weight

40kg

CGF application

1. Move skin wrinkles, Improve skin dryness, relaxation, dullness, spots, pore size and other phenomena.            

2. Skin anti-aging            

3. Promote tissue regeneration, Repair of wounds and scars            

4. Reconstruction of skin barrier and repair of tissue            

5. Lipid transplantation partners to improve the survival rate of fat transplantation            

6. Scalp management            

7. Treatment of mesodermal and osteoarthritis

CGF Therapy advantages

  1. CGF from autologous blood, no rejection reaction
  2. No Chemical additives, it’s safer
  3. With Various concentrated growth factors, a good effect
  4. The CD34 positive white cells promote the micro-circulatory system and collagen regeneration
  5. Multiple clinical uses – liquid/gelatinous without embolism risk

Compare 3 generations of blood-active substance PRP PRF CGF

Name

Separate results

Condition

construction

Molecular Structure

PRP

(Platelet Rich Plasma)

PPP+PRP+RBC

Anticoagulant

Liquid

Compact Tetramolecular structure

PRF

(Platelet Rich Fibrin)

PPP+PRF+RBC

No

Gel Membrane

3-dimension loose structure

CGF

(Concentrated Growth Factor)

PPP+CFG+PRP+CD34++RBC

No

Liquid Gel

Membrane Half-Gel

3-dimension looser structure

Compare of 3 generation of blood active substance PRP PRF CGF

Other Centrifuge